System controls

Lincoln's new product lineup for the natural gas compression industry. Innovative solution designed to protect your compressors against untimely lubrication faults or "no flow" conditions.

Model 87630 Datalogger lubrication monitor
  • Three mounting options
  • Two primary power sources available
  • Continuously monitors the packing and cylinder lubrication system
  • Download feature allows history to be transferred to a CSV report via a USB flash drive in less than a minute
  • Store data for up to one year
  • No special software or hand-held hardware device needed
  • One model will monitor either a single or dual lubrication system
  • Designed for use with Reed or Hall effect cycle switches
Input power 10-30 VDC, 0.25 amp max.
Internal battery 3.6V Long-life lithium tardiran TL-5930, battery life: 4-6 years
Output switches 2 each open drain sinking FET's, rated 30 VDC 500mA max.
Ambient temp. range: Operation: -40°F to 185°F (-40°C to 85°C)
LCD -4°F to 158°F (-20°C to 70°C)
USB download 32°F to 158°F (0°C to 70°C)
Display 2x16 backlit character
Input cycle range: 5 to 300 seconds
Units of measure: Pints, liters or gallons
Alarm time: Adjustable from 5 to 300 seconds
Switch response time: 250 mS max.
USB download port: USB 2.0 compliant, accepts universal flash drive
Data log file format: Comma-separated Values file (CSV) for use in programs including Microsoft® Excel
EX rating: Class I, Groups A, B, C & D, Div. 2 CE, II 3G Ex Na IIA
Outlet thread: 1/2 in. NPT(F)
Cycle switch and accessories for use with datalogger lubrication monitor

Designed to work with Lincoln MC, MC2-HP valves as well as with other brands. Simple installation reduces labor costs. Features captured magnet assembly and Hall effect switch. The industry's first cycle switch with a cycle indicator light.

For models 249120, 249122, 87617:

  • Power requirements: 5 to 30 VDC, 100 UA max.
  • Maximum working pressure: 7500 psi (517 bar)
  • Temperature range: -40°F to 185°F (-40°C to 85°C)
  • Construction: Aluminum housing, stainless steel magnet assembly
  • EX rating: Approval pending for Class I, Groups A, B, C & D, Div. 1 & 2 CE, II 3G Ex Na IIA
249120 Hall effect cycle switch for Lincoln MC2-HP series blocks
249122 Hall effect cycle switch for Lincoln UV and Graco Lubriquip®-Manzel MHP series style block
87617 Reed type cycle switch for Lincoln MC and MC2-HP series block
250001 Wall mounting bracket for 87630
249125 EX housing, rated Class 1, Div 1 & 2, Group B, C, D
250002 Internal 3.6v lithium replacement battery
250010 Replacement USB port cap

Model 84501 Program timer - solid state
Designed to control the lubrication cycle frequency of air-operated single-stroke pumps. Timer turns pump on/off at programmed intervals via a 3-way or 4-way air solenoid valve (not included) installed in the air line to pump.

  • Power requirements: 120/230 VAC, 50/60 Hz
  • Switch capacity: 120 VAC, 5 amps / 230 VAC, 1.5 amps
  • Ambient operating temp range: 0°F to 130°F (-18°C to 54°C)
  • Refer to technical manual for full explanation of available program options
20 sec 24 hrs 10 sec 84 sec Yes/No Yes/No 8-1/4 210 6-13/16 173 4-15/16 125 NEMA #1
Model 84511 Economy timer for single stroke pumps

Uses a timing motor, cam and micro-switch to turn pump off and on.

  • Power requirements: 120 VAC, 60 Hz
  • Switch capacity: 10 amps non-inductive
  • Approvals: UL, CSA
  • Rating: NEMA 1
  • Off-time selectable in 5 minute intervals
5 Min. 1 Hr. 30 sec 90 sec 5 127 3-1/4 82.5 3-1/2 89
Model 84015 Timer 12/24 VDC

Solid-state microprocessor-based controller for automated lubrication systems on mobile equipment or where AC power is not available. Rugged construction with liquid- and dust-tight enclosure. Includes manual push-button for remote initiation of a lube cycle.

  • Power requirements: 10-30 VDC, 25 mA
  • Switch capacity: 5 amps
  • Ambient operating temp. range: 0°F to 131°F (-18°C to 55°C)
  • Rating: NEMA 12
  • Available off-time selections: 2.5, 5, 10, 20, 40 or 80 minutes
2.5 Min. 80 Min. 75 sec. 5-1/4 133 3-1/8 79 3 76
LMC 101 Lubrication system controller

Developed for use on off-road and mobile equipment, the LMC 101 controller operates as a timer or controller on single-line or progressive lubrication systems. Operates single-line or progressive lubrication systems

  • Controls FlowMaster or high-current pump without external relay
  • Uses pressure switch or pressure transducers (1 to 6 V or 4 to 20 mA) in controller mode
  • Four inputs:
    – Two pressure switches, pressure transducers or piston detectors
    – Remote manual lubrication switch
    – Low-level switch
  • Four outputs:
    – Pump
    – Low-level alarm relay
    – System fault relay
    – Vent solenoid
12 or 24 V DC, -20% + 30%
-40 to 150°F (-40 to 66 °C) 7.3 186 4.7 120 2.3 59
                         
LMC 301 Lubrication system controller

For reliable control of small, large or multi-system-type lubrication systems.

  • IP 65-rated container for water resistance
  • Available in 24 V DC or 110 or 220 V AC
  • Modular system with 10 inputs per unit
  • Up to seven IO extensions per system
  • USB connection mode
  • Pump settings include time- or pressure-
    based lubrication, pump control
    and temperature monitoring
  • Approvals: UL/CSA/CE
100-240 V AC (47-63 Hz) 4 A 24 V DC ±10% 10 A 10.6 270 6.7 170 3.5 90
                   
Model 247333 Pressure transducer

Pressure transducer signals actual system pressure. Comes with 72 in. (1.8m) shielded 24 ga. connecting wire. Maximum length of wire between transducer and monitor is 30 ft. (9.1m).

  • Power requirements: 10 to 30 VDC
  • Voltage output: 1-6 VDC
  • Offset: 1 VDC
  • Rating: NEMA 4X
  • Enclosure: Stainless steel
0 to 4000 psi (276 bar) +/- 1% 1/4 in. NPT(M) 7500 517 -20 to 180 -29 to 82
Electric solenoid-operated air valves
  • Max. Pressure: 150 psi (10.3 bar)

Model 350244

350244 4-way 110 VAC, 50 Hz
120 VAC, 60 Hz
8.4 VA
.11 .07 1/4 0 to 120 -18 to 49 1.2 1/2 NPS(F)
350245 4-way 220 VAC, 50 Hz
240 VAC, 60 Hz
8.4 VA
.055 .035 1/4 0 to 120 -18 to 49 1.2  1/2 NPS(F)
350241 3-way 110 VAC, 50 Hz
120 VAC, 60 Hz
8.4 VA
.11 .07 1/4 0 to 140 -18 to 60 .18 1/2 NPS(F)
350242 3-way 220 VAC, 50 Hz
240 VAC, 60 Hz
8.4 VA
.055 .035 1/4 0 to 140 -18 to 60 .18 1/2 NPS(F)
350282 3-way 12 VDC, 6 watts - - 1/8 0 to 140 -18 to 60 .18 -
350283 3-way 24 VDC, 6 watts - - 1/8 0 to 140 -18 to 60 .18 -
68586 2-way 120 VAC, 60 Hz
12 VA
.2 .1 3/8 0 to 140 -18 to 60 2.4 1/2 NPT(F)
274398 3-way 24 VDC, 8.5 watts - - 1/4 0 to 140 -18 to 60 .5 -
244727 3-way 110 VAC, 50 Hz
120 VAC, 60 Hz
11 VA
.12 .09 3/8 0 to 120 -18 to 49 4.4 1/2 NPT(F)

Model 350283

Model 350241

Model 68586